05 — Quality & Compliance

In-House JAS Laboratory & Third-Party Certifications

Rigorous daily testing per production batch for cyclic boil shear strength, moisture tolerances (8–12%), and desiccator formaldehyde emissions conforming to Japanese F★★★★ and US EPA TSCA Title VI standards.

05 — Quality control mill QC standard

The lab is on site, and it tests your batch — not a demo panel

Every product family we ship is tested against a named standard. The table below is the QC specification we work on plywood — the same items appear on the batch release sheet that accompanies your shipment. JAS/JIS for the Japanese market, EPA TSCA Title VI for the United States, SVLK for origin. methods per mill lab record — ask for a sample sheet

Test item Method Standard value
Formaldehyde emission JAS / JIS F★★★★ / F★★★ / F★★
Formaldehyde emission — US market TSCA Title VI (US EPA / CARB) F★★★★ · Phase 2 ≤ 0.05 ppm
Bonding strength TS / WBP exterior · T1 exterior Min 0.7 N/mm²
Delamination T2 / interior Delamination test
Moisture content (MC) Oven 100 °C ≤ 14%
Bending test JAS °/ 90° (long. / cross) Class 1 / Class 2
Panel saw JAS Class 1

Values as issued in the mill testing specification (item / method / standard). Actual pass per batch is recorded on the release sheet; F-star grades are only claimed where the destination certificate supports them.

In-line thickness gauge scanning finished panels
In-line thickness detector machine
  1. 01 Log intake & species record
  2. 02 Veneer gauge & moisture after dryer
  3. 03 Core patching & butt-joint check
  4. 04 Glue spread weight
  5. 05 Press cycle log per panel
  6. 06 Thickness calibration after sanding
  7. 07 Face/back grade sight check
  8. 08 Squareness & edge condition
  9. 09 Emission & boil test per batch
  10. 10 Tally, packing photo, document set